1. Diagnosis by Malfunction Code

1.1

Diagnosis by Malfunction Code

Malfunction code
Troubleshooting Inverter K Series
Malfunction contents
A0
Indoor unit: Error of external protection device
A1
Indoor unit: PC board defect
A3
Indoor unit: Malfunction of drain level control system (33H)
A6
Indoor unit: Fan motor (M1F) lock, overload
A7
Indoor unit: Malfunction of swing flap motor (M1S)
A9
Indoor unit: Malfunction of moving part of electronic expansion valve
(Y1E)
AF
Indoor unit: Drain level above limit
AJ
Indoor unit: Malfunction of capacity determination device
C4
Indoor unit: Malfunction of thermistor (R2T) for liquid pipe
C5
Indoor unit: Malfunction of thermistor (R3T) for gas pipes
C9
Indoor unit: Malfunction of thermistor (R1T) for air inlet
CJ
Indoor unit: Malfunction of thermostat sensor in remote controller
E0
Outdoor unit: Actuation of safety device
E1
Outdoor unit: PC board defect
E3
Outdoor unit: Actuation of high pressure switch
E4
Outdoor unit: Actuation of low pressure switch
E9
Outdoor unit: Malfunction of moving part of electronic expansion
valve (Y1E)
F3
Outdoor unit: Abnormal discharge pipe temperature
H9
Outdoor unit: Malfunction of thermistor for outdoor air (R1T)
J3
Outdoor unit: Malfunction of discharge pipe thermistor (R3T)
J5
Outdoor unit: Malfunction of thermistor (R4T) for suction pipe
J6
Outdoor unit: Malfunction of thermistor (R2T) for heat exchanger
JA
Outdoor unit: Malfunction of discharge pipe pressure sensor
JC
Outdoor unit: Malfunction of suction pipe pressure sensor
JH
Outdoor unit: Malfunction of oil temperature thermistor (R5T)
U0
Low pressure drop due to refrigerant shortage or electronic
expansion valve failure
U1
Negative phase, open phase
U2
Power supply insufficient or instantaneous failure
U4
Malfunction of transmission between indoor units
U5
Malfunction of transmission between remote controller and indoor
unit
U7
Malfunction of transmission between outdoor units
U8
Malfunction of transmission between main and sub remote
controllers
U9
Malfunction of transmission between indoor and outdoor units or
between outdoor units in the same system
UA
Excessive number of indoor units
Improper combination of indoor and outdoor units (incompatible
refrigerant), improper number of connected indoor units or remote
controllers (inappropriate remote controllers), faulty PCB model
setting (replacement PCB)
UC
Address duplication of central remote controller
UF
Refrigerant system not set, incompatible wiring/piping
UH
Malfunction of system, refrigerant system address undefined
The system operates for malfunction codes indicated in black squares, however, be sure to
check and repair.

Diagnosis by Malfunction Code

Fan operation
Page
77
78
79
8
80
81
8
82
8
83
84
85
8
86
8
87
8
88
8
89
90
91
92
8
93
8
94
8
95
8
96
8
97
8
98
8
99
8
100
8
101
8
102
8
103
8
120
8
104
8
105
106
8
107
8
108
8
109
8
110
8
111
8
112
8
75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents