Installation Instructions Open Burner

Special Countertop Conditions

Countertops such as ceramic tile tops cause cabinet
and countertop to be higher than 36 inches. Follow
instructions below when countertop is higher than 36
inches.
1. Raise leveling legs to maximum level.
2. Measure from floor to side trim. If measurement is
less than height of countertop, floor must be
shimmed.
3. Shim floor using a piece of plywood same size as
range opening. Secure plywood to floor. Plywood
must be as secure as original flooring.
4. Install anti-tip bracket(s) and slide range into place.

Gas Connection Requirements

Before connecting this appliance to the gas supply
piping system, confirm installation meets the
requirements of local codes, or in the absence of local
codes, with the National Fuel Gas Code,
ANSI Z223.1-Latest Edition.
The installation of appliances designed for
manufactured (mobile) home installation must conform
with Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, or when such
standard is not applicable, the Standard for
Manufactured Home Installation,
ANSI225.1/NFPA 501A-Latest Edition, and with local
codes where applicable.

Gas Supply Location

Gas supply must be located in the area shown.
A
B
A—26 inches
B—20 inches
C—2¼ inches
D—4 inches
E—6 inches
RS2310004 Rev. 1
C
D
E

Gas Supply Pressure

!
To avoid property damage, maximum gas supply
pressure must not exceed 14" WCP.
• Appliance and individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of ½ psig (3.5kPa) (14" WCP).
• Appliance must be isolated from gas supply piping
system by closing manual shutoff valve during any
pressure testing of the gas supply piping system at
test pressures equal to or less than ½ psig (3.5kPa)
(14" WCP).
• Gas supply pressure for checking regulator setting
must be at least 1" WCP above manifold pressure
shown on rating label.

Pressure Regulator Location

Remove rear cover to expose pressure regulator.