Pulse Train Generator

Pulse waveforms can be output from the GPO2/3
connector. Available range is 0.5Hz to 100kHz.
Register
PWMPulseDutyT
1 to 2000000 [µs]
PWMPulseCycleT
10 to 2000000 [µs]

Status LED

The LED-on, blinking, or LED-off condition of the LED
on the rear panel is as follows:
LED-on
Power is turned on and an IP address is
set.
Blinking (low speed)
Power is turned on and an IP address is
not set.
Blinking (high speed)
Power is turned on and the reset button
is pressed down.
LED-off
Power is turned off or during startup.
Temperature Readout
Function
The camera's internal temperature can be read from the
temperature sensor installed in the circuit board. Its
accuracy is ±2°C. Use this value as a general guide.
If the interval of the temperature sensor value is set to a
value other than 0, the temperature information can be
transmitted to a PC application as an event data.
Register
Parameter
CameraTemperature
CameraTemperature-
32-bit
MeasurementInterval
integers
Parameter
Setting
Temperature sensor value
Update interval of the
temperature sensor value
[second]

Sensitivity Control

The VSUB (substrate bias voltage) in the CCD can be
1
changed*
. VSUB adjustment allows you to change the
Qs (saturation signal charge) value. Increasing the
VSUB has the effect of improving the sensitivity*
Therefore, when capturing a dark image but the
exposure time cannot be extended, this has the effect of
improving the image quality. On the other hand,
decreasing the VSUB has the effect of reducing image
smearing. The factory setting is adjusted to the optimal
value.
1
*
Not including XCG-C130 and XCG-C130C
2
*
If Qs exceeds the maximum signal charge amount
that can be transferred vertically and horizontally, a
transfer error will occur, resulting in image smearing,
etc.
Register
Parameter
VsubExternalMode On (0)
Off (1)
VsubExternalValue 0 to 127

User Set

Main set values can be saved to the channels 1 to 16 of
USERSET. Refer to "Command List" (page 37) for
items to be saved. The factory setting is saved to channel
0, which cannot be overwritten.
Setting example (1):
Shutter is 3 ms, Gain is 3 dB, Pulse signal is output to
GPO3 connector (this setting is saved to the channel
1).
ExposureTime=3000
Gain=3
LineSelector=Line3
LineMode=Output
LineSource=PWM
UserSetSelector=1
UserSetSave
Setting example (2):
The user set saved in the channel 2 is loaded.
UserSetSelector=2
UserSetLoad

User set memory

This is one of the items to be saved in the user set
channel. Signed 32-bit numbers are assigned to slots 0 to
15.
2
.
Setting
Sensitivity adjustment off
Sensitivity adjustment on
Sensitivity adjustment
value
35