Sequential
SpecialTriggerMode=2, SpecialTriggerActivation=0 in the figure.
Trigger signal
Sensor output
Trigger states

Trigger source

This can be input via the DC IN connector or software command (TriggerSoftware). Refer to "Trigger Signal Input"
(page 14) for details. Note that the trigger sources for the special trigger operation and the trigger mode operation are
defined separately.

Trigger inhibition

Trigger input can be disabled. This function is effective when disabling the trigger signal to a specific camera in the
environment where multiple cameras are connected by the same trigger signal and when preventing false operations
caused by noise contamination to the trigger signal line (due to the installed environment).
Trigger signal
Trigger inhibition
Exposure
Sensor output
Register
Parameter
TriggerInhibit
Off (0)
On (1)
Exposure
Setting 1
5ms or
longer
Trigger mode
Setting
Trigger is accepted
Trigger is not accepted
Setting 2
Free run
Bulk
Sequential
Trigger
disabled
Setting 3
Trigger edge detection
Trigger width detection
Trigger Control