Trigger range operation example
ExposureTime=300, TriggerAcceptanceRangeLowerLimit=100, TriggerAcceptanceRangeUpperLimit=200 in the
figure.
Trigger signal
Exposure
Sensor output
ExposureTime=300, TriggerAcceptanceRangeLowerLimit=100, TriggerAcceptanceRangeUpperLimit=1000 in the
figure.
Trigger signal
Exposure
Sensor output
Trigger control
Since detection of the trigger width time requires a certain time during the trigger width detection operation, the
exposure time will be slightly longer than the input trigger width time. To perfectly match with the trigger signal width
period, TriggerControl should be set to 0. TriggerShift=1 and TriggerControl=0 cannot be set at the same time. Refer
to "Trigger latency" (page 28) for details.
24
Trigger Control
Trigger not disabled