7.6 THERMAL FUSE REPLACEMENT

1.
Remove the fusing knob [A] and the fusing front cover [B]. (See the
Fusing Lamp Replacement section.)
2 .
Remove the fusing unit upper cover [C] (4 screws).
3 .
Lower the paper exit assembly [D].
4.
Pull out the temperature fuse connector [E].
5.
Disconnect the fuse harness lead from the rear terminal [F] of the fusing
lamp (1 screw).
6 .
Remove the temperature fuse [G] (1 screw, 2 plate clamps).
7.
Replace the temperature fuse.