General Technical Data
10.1

Menu Structure

Display measured value
ESC
ESC
OK
Phase voltages
Device status
UL1N
Active parameter set
UL2N
Parameter set 1
UL3N
Parameter set 2
Phase-to-phase voltages
Parameter set 3
UL1-L2
Type of connection
UL2-L3
Unknown/faulty
UL3-L1
Star/delta
Blocking voltages
Inside delta
ULT1
Direction of rotation
ULT2
Unknown
ULT3
Clockwise
Phase currents
Counter-clockwise
IL1
Inputs
IL2
Status - Inputs
IL3
Input 1 - Action
Power
Line frequency
Supply voltage
Heatsink temperature
Motor heat build-up
Remaining time for tripping
Switch off standard display
Input 2 - Action [...]
Input 3 - Action [...]
Input 4 - Action [...]
Outputs
Status - Outputs
Output 1 - Action
Output 2 - Action [...]
Output 3 - Action [...]
Output 4 - Action [...]
Order number
Firmware information
Version
Date
** Possible only in connection with creep speed
10-2
Status display
OK
ESC
Parameter set 1
Motor 1
Rated operating current Ie
Rated operating torque
Rated operating speed
Copy motor data to PS2 + 3
Starting settings
Starting mode
Voltage ramp
Voltage ramp + current
limiting
Torque control
Torque control + current
limiting
Direct on line
No action
Motor heating
Manual operation
Start voltage
local
Start torque
Emergency start
Limiting torque
Slow speed
Starting time
Quick stop
Maximum starting time
Trip reset
Motor right PS1
Current limiting value
Motor left PS1 **
Breakaway voltage
Motor right PS2
Breakaway time
Motor left PS2 **
Motor thermal capacity
Motor right PS3
Stopping settings
Motor left PS3 **
Stopping mode
Coasting down
Torque control
Pump stop
DC braking
Combined braking
Stopping time
No action
Stopping torque
PIO output 1
Dynamic braking torque
PIO output 2
DC braking torque
Input 1
Slow speed parameters
Input 2
Slow speed factor right
Input 3
Slow speed torque right
Input 4
Slow speed factor left
Run up
Slow speed torque left
Bypass operation
Current limit values
Coasting down
Minimum current limit value
On-time motor
Maximum current limit value
Command motor-on
Parameter set 2 [...]
DC braking contactor
Parameter set 3 [...]
Group warning
Inputs
Group error
Input 1 - Action
Bus error
No action
Device errors
Manual operation local
Power on
Emergency start
Ready to start
Slow speed
Quickstop
Trip Reset
Motor right PS1
Motor left PS1 **
Motor right PS2
Motor left PS2 **
Motor right PS3
Motor left PS3 **
Input 2 - Action [...]
Input 3 - Action [...]
Input 4 - Action [...]
Settings
Factory
Customer
OK
Settings
Settings
Depends on
order
number
0
1,500
x
30 %
10 %
150 %
10 s
0/
deactivated
400 %
40 %
0 ms
20 %
x
10 s
10 %
50 %
50 %
7
50 %
7
50 %
18.75 %
112.50 %
x
No Action
No Action
Trip Reset
Outputs
Output 1 - Action
No action
PIO output 1
PIO output 2
Input 1
Input 2
Input 3
Input 4
Run up
Operation / bypass
Coasting down
On-time motor
Command motor-on
DC braking contactor
Group warning
Group error
Bus error
Device errors
Power on
Ready to start
Output 2 - Action [...]
No Action
Output 3 - Action [...]
No Action
Motor protection
Tripping class
None
CLASS 5 (10a)
CLASS 10
CLASS 15
CLASS 20
CLASS 30
Current asymmetry limit value
Prewarning limit tripping reserve
Prewarning limit motor heat
build-up
Idle time
Pre-charge time
Protection against voltage failure
No
Yes
Temperature sensor
Deactivated
Thermo click
PTC-type A
Display settings
Language
English
Deutsch
Français
Español
Italiano
Português
Nederlands
Ελληνικά
Türkçe
Русский
中文
Contrast
Lighting
Brightness
Lighting on
Off with time delay
Lighting off
Response to fault
Unchanged
On
Blinking
Flickering
SIRIUS 3RW44 manual
GWA 4NEB 535 2195-02 DS 06
Factory
Customer
Settings
Settings
x
x
40 %
0 s
80 %
0 s
60 s
x
x
x
50 %
x
x