1. HOW TO INSTALL THE SYSTEM
6. Apply a slight amount of lithium grease to the threads of the bolts to prevent
scorching. Insert the bolts with washers from the retraction tank flange, and then
put the flat washers and spring washers in this order from above. Fasten bolts with
nuts.
Attachment flange OP-38/39/43/44
When retrofitting CSH series or FSV-243E/244E, use the
insulated gasket from the Attachment kit OP10-24
Bow side (17 places)
Insulated
gasket
Insulated
packing
Spring washer
Hex nut
Stern side (7 places) is secured using stud bolts, flat
washers, spring washers and 2 x hex nuts.
7. Reinforce the attachment flange using reinforcement ribs.
80 to 100 mm
Note: For installations requiring welding of the reinforcement ribs:
1) Temporarily remove the insulated gasket, insulated packing and O-ring.
2) Temporarily install the attachment flange, then install and weld the reinforce-
ment ribs.
3) Remove the attachment flange, then replace the insulated gasket, insulated
packing and O-ring.
4) Follow step 6 above.
1.11

Remote Controller (FSV-2504)

Use the optional fixing material (Type: OP10-9, code no. 006-990-040) to install the
optional remote controller in a location away from spray and splash. Use the outline
drawing at the back of this manual for reference.
1-18
Hex bolt
Flat washer
Flat washer
Spring washer
O-ring
Attachment
flange
Hex/stud bolt
Flat washer
Spring washer
Hull unit flange
Hex bolt
Flat washer
O-ring
Hex nut
O-ring
Hex nut
Retraction tank
Attachment flange
Reinforcement ribs