2. WIRING
2.2

Processor Unit

Referring to the figure below, connect external units to the processor unit via the front
panel of the processor unit. Make sure all cables are securely connected.
IF Unit
10S2383, 3 m
FSV-8502
DPYC-2.5
(Less than 5 m)
12-24 VDC
Power cable fabrication
1. Referring to the figure below, fabricate a DPYC-6 marine power cable (Maximum
length 5m, local supply.)
2. Remove the power terminal cover at the rear of the processor unit (See figure
below), then connect the DPYC-6 power cable. (Upper terminal is +, lower
terminal is -.)
3. Replace the power terminal cover to its original position.
4. Connect the processor unit earth to the ship's earth with a ground wire (IV-8.sq,
local supply).
47
Outer sheath
Cut and remove the outer sheath
7
8 to 12
Wrap with insulated tape
5.5
Crimp-on lugs (local supply)
2-2
Transceiver unit
19S1050, 3 m
FSV-251
FR-FTPC-CY
(100 m or less)
Ground
wire IV-8sq.
To ship's earth
3
Cable jacket
20
IF Unit
FSV-5802
External monitor
(SXGA, UXGA, WUXGA)
DVI-D/D SLINK
(5 m or 10 m)
PC speakers with amplifier
(5 W or less, local supply)
Sub controller
(FSV-853, option)
NMEA 0183 Equipment
All dimensions in millimeters
Power terminals
Power terminal cover