3. POST INSTALLATION SETTINGS
3.3

Hull Unit Checks

Note 1: To avoid damage to the equipment, do not transmit while dry docked.
Note 2: When performing maintenance to the hull unit and checking the movement,
make sure that the power is on only to the hull unit and perform all checks in test mode
to avoid accident or injury.
Note 3: Make sure all connections to the hull unit are made correctly, referring to the
wiring table attached to the hull unit, to prevent the shaft from being dislodged.
How to check transmit status
Note: "Select" means move the cursor, using the trackball. Then, when highlighting a
menu option, click the left button on the trackball to select the highlighted item.
Transmission is set to [OFF] as factory default. You can check and change the status
by doing the following.
1. Press the MENU/ESC key to open the menu. The main menu window will be
displayed.
2. Select [Others] to display the [Others] menu.
3. Select [Initial Setting] to display the [Initial Setting] menu.
4. Select [Changeable].
5. Select [Test] to display the [Test] menu.
6. Select [TX].
7. Select [OFF] or [ON] as appropriate, then press the left button.
8. Select [Quit] to apply the settings.
9. Press the MENU/ESC key to close the menu.
3-4
Test
Operation Test...
: Execute
Board Test...
: Execute
Panel Test...
: Execute
Test Pattern...
: Execute
RX Test...*
: Execute
FAN MONITOR
: Execute
TX
: OFF
Test menu
Quit
* For technician