Load Cell - Dual - Siemens Milltronics BW100 Instruction Manual

Integrator for belt scales
Table of Contents

Advertisement

Load Cell - Dual

BW100
TB1
UPPER
SIG B
+
SIG B
SIG A
+
SIG A
CNST. SPD.
+
+
SHIELD
Where separation between the BW100 and belt scale exceeds 150 m (500 ft.):
1.
remove the jumpers BW100 TB1 – 17/18 and TB1 19/20
2.
run additional conductors from:
BW100 TB1 – 18 to scale '– EXC'
BW100 TB1 – 19 to scale '+ EXC'
If the load cell wiring colours vary from those shown, or if extra wires are provided,
consult Siemens Milltronics.
Page 10
BW100
TB1
LOWER
EXC
SEN
SEN
EXC
Milltronics BW100 - INSTRUCTION MANUAL
' A '
s
r
b
h
e
l
l
d
k
d
Note:
If load cells are supplied with
sense wiring:
terminate brown with black = T17
and blue with red = T20
at junction box
'B
Belt Scale
load cells
w
g
w
g
h
r
h
r
t
n
t
n
customer
junction
box
7ML19985DJ01