Siemens Milltronics BW100 Instruction Manual page 70

Integrator for belt scales
Table of Contents

Advertisement

message
E101 (run)
E102 (run)
E103 (run)
E104 (run)
OF
Error messages are cleared when the condition is remedied.
RUN mode errors are suppressed during PROGRAM mode, zero or span calibration.
Zero and span errors are cleared when zero or span is initiated. Errors that happen
during the calibration require re-starting the procedure.
Program errors are cleared when any key is pressed.
The messages E101 through E104 can be turned off (P949).
The load cell errors are detected by certain conditions where it is apparent that the
load cell is not functioning or incorrectly wired. It is not a conclusive test, since even
with incorrect wiring, the resulting input from the load cell may be within a valid
range.
Page 66
diagnosis
load cell A mV reading is out
of range
load cell B mV reading is out
of range
combined mV signal from
load cell A and B is out of
range
faulty memory location found
no speed signal
Milltronics BW100 - INSTRUCTION MANUAL
action
error will appear if:
• mV signal from load cell A or
B is out of the 0-50 mV range
• the mV signal from load cell
A or B is less than the zero
calibration mV level minus
one half the span mV level
• A or B mV is greater than 4
times the span mV value
check load cell mV signal and
ensure that it is within range
check wiring
error will appear if the com-
bined mV signal from load cell
A and B is too low
check both load cell signals
and ensure that they are
greater than 0 mV
check wiring
cycle power and perform mem-
ory test (P901)
if error reappears, the BW 100
must be repaired or replaced.
check speed circuit or run con-
veyor
7ML19985DJ01