Siemens Milltronics BW100 Instruction Manual page 60

Integrator for belt scales
Table of Contents

Advertisement

P350 Calibration Security
This parameter provides additional security to the global lock (P000).
Entry:
0 = view parameters, perform zero and span, no reset of totalizer 1
1 = same as level 0, but cannot perform span
2 = same as level 0, but cannot perform zero and span
P359 Factoring
Factoring is used as a method of calculating the value of the test load (P017) to a new
physical test weight.
Entry:
0 = idle
1 = factor
Note:
Totalization is halted during the factoring procedure, and resumed only
upon return to the RUN mode.
P360 Calibration Duration
Sets the number of belt revolutions to use during a zero or span calibration.
Enter number of belt revolutions, range 1 - 99.
P367 Direct Zero
This parameter allows the zero reference count to be viewed or entered directly.
Direct entry is intended for use when replacing software or hardware and it is not
convenient to perform an initial zero at that time.
P368 Direct Span
This parameter allows the span reference count to be viewed or entered directly.
Direct entry is intended for use when replacing software or hardware and it is not
convenient to perform an initial span at that time.
P370 Zero Limit
Sets the zero calibration deviation limit from the last initial zero. If the accumulated
deviation exceeds the limit, the zero calibration is aborted (E3).
Entry:
0 = +/- 12.5% of initial zero
1 = +/- 2% of initial zero