4. Technical data

Rated voltage
Rated current
Mains frequency
Torque
Revolutions (counter-clockwise)
Impact energy
Dimensions
Drill bit head diameter
Drill steel length
Protection class I
Storage temperature without cooling water
Noise and vibration information
(measured in accordance with EN 60745-2-6) under load
Typical A-weighted sound power level:
Typical A-weighted emission sound pressure level:
Wear ear protection!
For the given noise level in accordance with EN 60745-2-6,
measurement uncertainty is 3 dB.
Typical weighted vibration TE MD20 in concrete a
Uncertainty (K)
Weight according to EPTA-Procedure 01/2003
Protection against entry of water or foreign objects
Explosion protection
Right of technical changes reserved.
-NOTE-
The vibration emission level given in this information sheet has been measured in accordance with a standardised
test given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assess-
ment of exposure. The declared vibration emission level represents the main applications of the tool. However if the
tool is used for different applications, with different accessories or poorly maintained, the vibration emission may
differ. This may significantly increase the exposure level over the total working period. An estimation of the level of
exposure to vibration should also take into account the times when the tool is switched off or when it is running but
not actually doing the job. This may significantly reduce the exposure level over the total working period. Identify
additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
Printed: 08.07.2013 | Doc-Nr: PUB / 5071845 / 000 / 01
TE MD20 LS T
TE MD20 LS T HA
TE MD20 LS T EM
TE MD20 LS T IM
220–240 V single phase
15 A
50–60 Hz
100 Nm
205 r.p.m.
28 J
770×210×230
28–51 mm
up to 2,4 m
Protection class I
–20°C to +55°C
109 dB (A)
98 dB (A)
:
11 m/s
2
h, HD
2 m/s²
27,7 kg
Plug: IP 66, IP 67
Tool: IP 66
I M2 / II2 G 94/9/EG
EEx d I/IIA T4
TE MD20 LS T PRCD
TE MD20 LS T HA PRCD
TE MD20 LS T EM PRCD
220–230 V single phase
15 A
50–60 Hz
100 Nm
205 r.p.m.
28 J
770×210×230
28–51 mm
up to 2,4 m
Protection class I
–20°C to +55°C
109 dB (A)
98 dB (A)
11 m/s
2
2 m/s²
27,7 kg
Plug: IP 44
PRCD: IP 55
Tool: IP 66
No explosion
protection
17