7.3.14 "Remove Output from Standard Bin" Message (C5: Full
Stack)
Initial Action
In this case, C5 is a Status Code that usually appears when trying to reproduce a Bin-Full condition while
printing in the Diagnostics Mode. When a C5 "Full Stack" condition is displayed, please empty the
Output Bin.
1 Ensure the Stack Full Actuator remains actuated when it detects the presence of a full stack of
paper and deactuates when it does not detect a full stack.
Y:
Go to step 2.
N: Remove any obstructions that might be preventing the Bin Full Actuator from
deactuating into the home position before replacing the Bin Full Actuator.
2 The Stacker Full Sensor is functioning correctly. This can be checked using Diagnostic Mode 1,
Input Sensor Test.
Y:
Replace the Print Engine Controller.
N: Go to step 3.
3 The No Paper Sensor for the Tray Assembly is functioning correctly. This can be verified by
performing Diagnostic Mode 1, Input Sensor Test.
Y:
Replace the Print Engine Controller.
N: Go to RAP 7.4.14 Bin Full Sensor Failure.