1. Read the safety information to which "Preparing to remove and replace parts" on page 85 refers.
2. Confirm that you know which canister to replace. Go to "Procedure: Identifying which enclosure or
canister to service" on page 40.
3. Record which data cables are plugged into the specific ports of the node canister. The cables must be
inserted back into the same ports after the replacement is complete; otherwise, the system cannot
function properly.
4. Disconnect the data cables for each canister.
5. Grasp the handle between the thumb and forefinger.
Handles for the node canisters are located next to each other. The handle on the right operates the
upper canister. The handle on the left operates the lower canister.
Figure 19. Opening the handle on a canister
6. Squeeze them together to release the handle.
Figure 20. Removing the canister from the enclosure
7. Pull out the handle to its full extension.
8. Grasp canister and pull it out.