No enclosure identity and no node state
on partner
Explanation: The enclosure vital product data
indicates that the enclosure chassis has been replaced.
There is no cluster state information on the other node
canister in the enclosure (the partner canister), so both
node canisters from the original enclosure have not
been moved to this one.
User response: Follow troubleshooting procedures to
relocate nodes to the correct location:
1. Review the saved location information of the node
canister and why the second node canister from the
original enclosure was not moved into this
enclosure.
2. If you are sure that this node canister came from
the enclosure that is being replaced, and the original
partner canister is available, use the hardware
remove and replace node canister procedure to
install the second node canister in this enclosure.
Restart the node canister. The two node canister
should show node error 504 and the actions for that
error should be followed.
3. If you are sure this node canister came from the
enclosure that is being replaced, and that the
original partner canister has failed, continue
following the remove and replace procedure for an
enclosure chassis and configure the new enclosure.
Possible Cause-FRUs or other:
v None
507
No enclosure identity and no node state
Explanation: The node canister has been placed in a
replacement enclosure chassis. The node canister is also
a replacement, or has had all cluster state removed
from it.
User response: Follow troubleshooting procedures to
relocate the nodes to the correct location.
1. Check the status of the other node in the enclosure.
It should show node error 506. Unless it also shows
error 507, use these procedures to resolve the errors
on the other node.
2. If the other node in the enclosure is also reporting
507, the enclosure and both node canisters have no
state information. You should contact IBM technical
support. They will assist you in setting the
enclosure vital product data and running cluster
recovery.
Possible Cause-FRUs or other:
v None
78
Storwize V7000 Version 6.1.0: Troubleshooting, Recovery, and Maintenance Guide
508
Cluster identifier is different between
enclosure and node
Explanation: The node canister location information
shows it is in the correct enclosure, however the
enclosure has had a new cluster created on it since the
node was last shut down. Therefore, the cluster state
data stored on the node is not valid.
User response: Follow troubleshooting procedures to
relocate the nodes to the correct location.
1. Check whether a new cluster has been created on
this enclosure while this canister was not operating
or whether the node canister was recently installed
in the enclosure.
2. If this node canister is the one to be used in this
enclosure, you should follow the procedure to
remove cluster data from the node canister. It will
then join the cluster.
3. If this is not the node canister that you intended to
use, follow the hardware remove and replace
canister procedure to replace the node canister with
the intended one.
Note: If both nodes are reporting this node error, the
cause may be a damaged enclosure.
Possible Cause-FRUs or other:
v Service procedure error (90%)
v Enclosure chassis (10%)
509
The enclosure identity cannot be read.
Explanation: The canister was unable to read vital
product data (VPD) from the enclosure. The canister
requires this data to be able to initialize correctly.
User response: Follow troubleshooting procedures to
fix the hardware:
1. Check errors reported on the other node canister in
this enclosure (the partner canister).
2. If it is reporting the same error follow the hardware
remove and replace procedure to replace the
enclosure chassis.
3. If the partner canister is not reporting this error,
follow the hardware remove and replace procedure
to replace this canister.
Note: If a newly installed system has this error on both
node canister, the data that needs to be written to the
enclosure will not be available on the canisters, you
should contact IBM technical support for the WWNNs
to use.
Possible Cause-FRUs or other:
v Node canister (50%)
v Enclosure chassis (50%)