7.1.1.3 Extracting AI (Application Identifier)-prefixed strings
If the scanner reads any of GS1-128, GS1 DataBar, and GS1Composite symbols (excluding linear components in a
UPC/EAN Composite symbol), it edits the data according to AIs and outputs it in the data transmission format
selected in the scanner (see Chapter 9, Section 9.3).
The "AI-prefixed string" extraction is available in two modes--AI split mode and AI parenthesizing mode. AIs to be
used for data editing are listed in (3) AI table later.
(1) AI split mode
In this mode, the scanner extracts strings prefixed with AIs specified (up to three types of AIs) and separates them
with the specified delimiters (selectable from headers/terminators, commas and tabs) instead of AIs to output them.
 Extraction conditions
Extraction conditions
"Data transfer regardless of error result"
If the scanner fails to extract an AI-prefixed string when the "Data transfer regardless of error result" is permitted, it
outputs the data read as is without editing.
 Delimiters
 Header/terminator
Specifying a header/terminator as delimiters prefixes a header and suffixes a terminator to each element string
separated.
A scanner ID, code ID mark, the number of digits, prefix, and suffix can be also added to each element string if
their transmissions are enabled. The number of digits is the count of each element string edited.
Example
Data read: (01)94901234567894(11)030808(13)030810
Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable,
Transmission of the number of digits: Enable, Prefix/Suffix: None, BCC: Disable
AIs specified
01,11,13
 Comma
Specifying a comma as delimiters outputs comma-delimited data. No comma follows the tail of the data.
A header and terminator are added to the full string. None of a scanner ID, code ID mark, the number of digits,
prefix, and suffix is added even if their transmissions are enabled.
Example
Data read: (01)94901234567894(11)030808(13)030810
Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable,
Transmission of the number of digits: Disable, Prefix/Suffix: None, BCC: Disable
AIs specified
01,11,13
 Tab (ASCII 09H (HT))
Specifying a tab as delimiters outputs tab-delimited data. No tab follows the tail of the data.
A header and terminator are added to the full string. None of a scanner ID, code ID mark, the number of digits,
prefix, and suffix is added even if their transmissions are enabled.
Example
Data read: (01)94901234567894(11)030808(13)030810
Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable,
Transmission of the number of digits: Disable, Prefix/Suffix: None, BCC: Disable
AIs specified
01,11,13
Permit/Prohibit
[STX]94901234567894[ETX][STX]0006030808[ETX][STX]0006030810[ETX]
[STX]94901234567894,030808,030810[ETX]
[STX]94901234567894[TAB]030808[TAB]030810[ETX]
Choices
Output data
Output data
Output data