Control Panel

A Display: can display current water temperature, water tem-
perature set point, selected skimming/heating mode, and er-
ror messages.
B. ( + ) Button: increases water temperature set point.
C. ( - ) Button: decreases water temperature set point.
The range of temperature adjustment goes from 18 to 40 °C. Fac-
tory default setting is 38 °C.
D. Light button: switches the underwater light on and off.
Activates the LED lighting system, if present.
The light stays on for an hour and then switches off so that the
light bulb will last longer.
E. Pump 1 button: turns pump 1 on and off. Press once for low
speed; press a second time for high speed; press a third time
to turn pump off.
F. Pump 2 button (only for models with two pumps): turns pump
2 on and off. Press once to turn it on; press twice to turn pump
off.
The pump(s) will turn off automatically after 20 minutes. Press
the buttons again to reactivate the pumps for another 20 min-
utes.
G. Heat Indicator: lit when heater is on.

Operating instructions

The spa control system has automatic functions that operate
upon start-up and normal operation.
Upon power up, the display shows the following information:
I control panel displays current software release;
I All LED indicators are lit: check the operation of all display
segments and indicator lights.
I After the initial start-up sequence ends, the actual water
temperature is displayed. If water temperature is below 38° C
(factory setting) and the spa is set in skimming/heating
mode, the heater will come on.
N.B.: it is normal for the heater to turn on after the spa is first
filled because tap water is often very cold.
E
C
D
F
1
1
2
2
D
E
A
A
B
G
C
G
F
B
Setting water temperature
The spa's thermostat provides optimum control of water tem-
perature. The temperature set point (set temperature) can be
adjusted from 18 °C to 40 °C. To increase the set temperature,
press button (+). To lower it, press ( – ).
N.B.: The first press of either WARMER ( + ) or COOLER ( - ) but-
ton displays the set temperature.
The heater will turn off when the set temperature is reached; it
will be reactivated again when the temperature drops to ap-
proximately 1.5 °C with respect to the one set.
Pump activation
1
1
2
2
Button 1 activates the two-speed pump, the first press at low speed,
the second press at high speed. Pressing for a third time turns the
pump off. Button 2 activates pump 2, which only operates at high
speed.
Button for spotlight/LED lighting system
This button makes it possible to turn the spa light on.
The light stays on for an hour. This time can be extended by press-
ing the key again.
LED lighting system (J-210 mod.)
Offers 6 fixed colours and 1 random sequence modes.
I Press the "Spotlight" button once to turn on the light in "ran-
dom sequence"; press the button repeatedly to turn off the light
or to select one of the 6 fixed colour shades, based on the fol-
lowing order:
random sequence - off - red - off - green - off - blue
- off - orange - off - purple - off - acqua - off - random
sequence etc..
I Press the "Spotlight" button again within 5 seconds from
first pressing it; by pressing the button after 5 seconds the se-
quence restarts from the "random sequence".
LED lighting system (optional)
Offers 7 fixed colour shades and 3 random sequences.
I Press the "Spotlight" button once to turn on the light in
"random fading mode"; press the button repeatedly to turn off
the light or to select one of the 7 fixed colour shades, a ran-
dom sequence of fixed colours or a random sequence of flash-
ing colours, according to the following order:
random fading mode - off - WHITE - off - SKY BLUE - off - PUR-
PLE - off - BLUE - off - LIGHT GREEN - off - DARK GREEN - off -
RED - fixed random colours - flashing random colours - off.