Indesit ICD661UK Service Information page 19

Table top
Hide thumbs Also See for ICD661UK:
Table of Contents

Advertisement

Indesit
Company
C. WRAP ROUND OUTER CASE
1.
Open the dishwasher door.
2.
Remove the 6 Philips screws around the front of the
outer case.
3.
Remove the 8 rear Philips screws around the rear
of the outer case.
4.
Remove 1 Philips screw from under each outer
case side. Release 2 location tabs under each side
and 1 from each plinth.
5.
Lift the case away from the machine.
D. DOOR LOCK ASSEMBLY
1.
Remove the wrap round cabinet (C).
2.
Removed the 2 Philips screws securing the door lock assembly to the top edge of the inner door.
3.
Disconnect the electrical connections.
Note: - When refitting the door catch assembly, ensure the door catch assembly is correctly located
into the top edge of the inner door panel before tightening the fixing scews.
E. SOAP/RINSE AID ASSEMBLY
1.
Separate the inner and outer door panels (A).
2.
Noting the wiring connections release the locking tabs from the electrical terminals and remove.
3.
Remove the fixing screws from the 2 dispenser fixing brackets.
4.
The dispenser can now be removed from the inner door panel.
F.
ELECTRICAL CARDS & SELECTOR FITTED TO INNER DOOR PANEL
Note: - All these components are replaced as one unit including wiring.
Selector
On-Off Card
1.
Separate the inner and outer door panels (A).
2.
Remove the outer case (C).
3.
Remove all components from the outer door panel.
4.
On/Off Switch and Start/Pause Cards: - Remove 1 Philips fixing screw from each and lay the cards
to one side.
Service Manual UK
Start/Pause Card
19 of 28
Screws underneath case sides
LED Card
continued overleaf.......
English

Advertisement

Table of Contents
loading