Test Cycle - Indesit ICD661UK Service Information

Table top
Hide thumbs Also See for ICD661UK:
Table of Contents

Advertisement

Indesit
Company

TEST CYCLE

modify the font displayed
_ ___ __________ ___ _____ ___ _____ _____ ______
_______
_____
______
______
To start the Test Cycle:-
1.
Switch the machine off at (On-Off button). The machine must be 'OFF' to start the Test Cycle.
2.
Close the door and press the Power and Start/Pause buttons together until all LEDs flash
quickly.
3.
Press the Start/Pause button, to start the Test Cycle.
STEP
Initialize
Inlet Valve
Dispenser/
Wash Pump
Heating Element/
Wash Pump
Drain Pump
Pause
Inlet Valve
Wash Pump
Pause
Wash Pump
Drain Pump/
Softener Valve
Finish
Note: - During the Test Cycle the programme progress lamps will flash on and off in
sequence.
Service Manual UK
Power On, Stand-By
Inlet valve On and takes in water 1.9 litres (controlled by Flowmeter);
Dispenser opens and wash pump runs (60 seconds);
Wash pump runs and heating element on, up to 60°C (by thermistor);
NOTE: - To forward to the next step by press the Start/Pause button.
Drain pump (60 seconds);
(15 seconds)
Inlet Valve on, 1.9 litres (by Flowmeter);
Wash pump on (180 seconds);
(5 seconds);
Wash pump on (180 seconds);
Softener valve on and the drain pump (60 seconds);
1 Buzz test finishes, then power on again to Stand-By.