Omron V680-HAM91 User Manual page 171

Id flag sensors v680-series id system
Hide thumbs Also See for V680-HAM91:
Table of Contents

Advertisement

Applicable Models
V680-D1KP66T/MT
PPS resin is used for case material. Refer to the following lists and do not use chemicals that affect
PPS resin.
Chemical
Hydrochloric acid
Sulfuric acid
Nitric acid
Hydrogen fluoride solution
Chromic acid
Hydrogen peroxide solution
Sodium hydroxide solution
Ammonia solution
Sodium chloride
Sodium carbonate
A: Has no adverse effect, B: May cause discoloration, swelling, etc., C: Causes deformation, cracks, etc.
The above table shows the extent of changes in PPS resin exposed to each chemical at room temperature and at 90°C.
If actual chemicals, concentrations, and temperatures are different from those shown in the tables, always conduct tests
under the actual conditions in which the RF Tags are to be used.
V680-D1KP58HTN
At room
temper-
90°C
ature
37%
A
A
Sodium hypochlorite solution
10%
A
A
Phenol solution
98%
A
B
Glacial acetic acid
50%
A
A
Acetic acid
30%
A
A
Oleic acid
3%
A
A
Methyl alcohol
60%
B
C
Ethyl alcohol
40%
A
B
Ethyl acetate
10%
A
A
Sebacic acid diethylhexyl
40%
A
A
Acetone
40%
A
A
Diethyl ether
28%
A
B
n-heptane
3%
A
A
2-2-4 trimethylpentane
60%
A
A
Benzene
10%
A
A
Toluene
1%
A
A
Aniline
28%
A
B
Mineral oil
10%
A
B
Gasoline
10%
A
A
Insulating oil
20%
A
A
Dichloroethylene
2%
A
A
Carbon tetrachloride
Section 7
Appendices
At room
Chemical
temper-
ature
A
5%
A
A
A
A
95%
A
95%
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
RFID System
User's Manual
90°C
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A