Omron V680-HAM91 User Manual page 77

Id flag sensors v680-series id system
Hide thumbs Also See for V680-HAM91:
Table of Contents

Advertisement

I/O Specifications
Item
Transistor output or contact output
Input
Short-circuit current: 3 mA (typical) (Input terminal and 0-V short-circuit)
OFF voltage: 15 to 30 VDC
ON voltage: 0 to 5 VDC
Input impedance: 8.2 kΩ
Applied voltage: 30 VDC max.
NPN open collector,
Output
20 mA max. at 30 VDC,
residual voltage: 2 V max.
I/O Circuit Diagram
V680-HAM91
Input Circuit
DC24V
8.2kΩ
Main
IN
Circuit
Tr
0V
V680-HAM81
Input Circuit
DC24V
Tr
IN
Main
Circuit
8.2kΩ
0V
INPUT/OUTPUT controls
• When using a solid-state output with the maximum switching current rating over 1A , there is a possibility of causing
External Input Errors due to the delay of rise /fall time of output signal. Consider this when selecting the solid-state
output.
• When using a contact output, consider chattering and the minimum switching current.
• When connecting an inductive load or an electrical device that tends to generate noise to the output, connect a diode
in parallel with the load. Connect the cathode side of the diode to the positive side of the power supply.
V680-HAM91
Output Circuit
OUT
Main
Circuit
0V
Output Circuit
DC24V
Main
OUT
Circuit
0V
Appendices
V680-HAM81
PNP open collector,
20 mA max. at 30 VDC,
residual voltage: 2 V max.
RFID System
Section 7
75
User's Manual

Advertisement

Table of Contents
loading