7931 012
Remaining Toner
7931 013
Toner End
7931 014
Refill Flag
7931 015
R:Total Counter
7931 016
E:Total Counter
7931 017
Unit Counter
7931 018
Install Date
7931 019
Toner End Date
7931 020
Conductor Time1
7931 021
Conductor Time2
7931 022
Conductor Time3
7931 023
Conductor Time4
CartRidge Life
7932
Displays information about the cartridge service life.
• Returns a value of "0" if the number stored in the cartridge is not recognized.
• However, only 10 bytes can be used to communicate with
the controller, so the 16 bytes are truncated to 10 bytes.
Displays "0" to "100" (the percentage of toner remaining in the
cartridge)
N: Toner near end
E: Toner end
Displays "RF" when the cartridge requires refilling
Displays a number in the range "0" to "99999999", this is the
total count at time of installation.
Displays a number in the range "0" to "99999999", this is the
total count at toner end.
Displays a number in the range "0" to "99999999", this is the
total number of pages output by the AIO unit. Counter adds once
for each sheet output.
Displays Year-Month-Date of installation for the AIO unit, this
setting updates automatically through a serial interface with the
machine when the new unit is installed.
Displays Year-Month-Date when toner end occurred
Displays a number in the range "0" to "00000000", this is the
count for OPC.
Note:
• This information resides at four locations (020, 021, 022,
023. The recycle count determines where the value is
written.
• The counter increments by "1" for every 6 sec. of drum
rotation time.
• To calculate the actual time in sec., multiply the displayed
value by 6.
Printer Engine Service Mode
5
133