Communications Cycle Time Reference Table; Master User-Set Allocations Reference Table - Omron CJ1W-DRM21 Operation Manual

Machine automation controller cj-series, nj-series cpu unit
Hide thumbs Also See for CJ1W-DRM21:
Table of Contents

Advertisement

3 Data Exchange with the CPU Unit
3-3-4

Communications Cycle Time Reference Table

You can use this table to store the present, maximum and minimum communications cycle times in
milliseconds.
All the values in this table are cleared from the Unit and the maximum and minimum values are updated
with new values of when *_Sw1CycleTmClrCmd (Communications Cycle Time Reference Table Clear
Switch) is changed to TRUE.
In the case of automatic setting (default), the communications cycle time setting value is set to 0.
Name of device variable for
CJ-series Unit
*_CycleTmRefTblSta[0]
*_CycleTmRefTblSta[1]
*_CycleTmRefTblSta[2]
*_CycleTmRefTblSta[3]
3-3-5

Master User-set Allocations Reference Table

You can access the settings (area and size) for a maximum of four blocks (OUT block 1, OUT block 2,
IN block 1, and IN block 2) in the Master User-set Allocations Reference Table.
The OUT 1 and IN 1 block settings can be referenced if CX-Integrator is not being used.
Name of device variable for
CJ-series Unit
*_MstrAlocRefTblSta[0]
*_MstrAlocRefTblSta[1]
*_MstrAlocRefTblSta[2]
*_MstrAlocRefTblSta[3]
3-58
Type
R/W
Area
UINT
R
Communi-
cations
cycle time
setting
value
UINT
R
Communi-
cations
cycle time
present
value
UINT
R
Communi-
cations
cycle time
maximum
value
UINT
R
Communi-
cations
cycle time
minimum
value
Type
R/W
Area
UINT
R
OUT block
1 area
UINT
R
First word in
OUT block
1
UINT
R
No. of bytes
in OUT
block 1
UINT
R
IN block 1
area
CJ-series DeviceNet Units Operation Manual for NJ-series CPU Unit(W497)
Function
Indicates the the set value of communica-
tions cycle time.
Data range: 0 to 500
Default: 0
Indicates the present value of communica-
tions cycle time.
Data range: 0 to 65535
Default: 0
Indicates the maximum value of communi-
cations cycle time.
Data range: 0 to 65535
Default: 0
Indicates the minimum value of communi-
cations cycle time.
Data range: 0 to 65535
Default: 0
Function
Stores the OUT 1 area.
Data range: 0 to 20
Default: 0
Stores the first word for OUT 1 area.
Data range: 0 to 32767
Default: 0
Stores the size of OUT 1 area.
The OUT 1 block is not allocated if the
value is 0.
Data range: 0 to 1000
Default: 0
Stores the IN 1 area.
Data range: 0 to 20
Default: 0