4 Remote I/O Master Communications
Master User-set Allocations Setup Table
Name of device variables for
CJ-series Unit
*_MstrAlocTblCfg[0]
*_MstrAlocTblCfg[1]
*_MstrAlocTblCfg[2]
*_MstrAlocTblCfg[3]
*_MstrAlocTblCfg[4]
*_MstrAlocTblCfg[5]
Allocation Size Setup Table
Address
Bits 00 to 07 for D00100
Bits 08 to 15 for D00100
Bits 00 to 07 for D00101
Bits 08 to 15 for D00102
Bits 00 to 07 for D00103
Bits 08 to 15 for D00103
Bits 00 to 07 for D00104
Bits 08 to 15 for D00104
Bits 00 to 07 for D00105
Bits 08 to 15 for D00105
Bits 00 to 07 for D00106
Bits 08 to 15 for D00106
Resulting Slave Allocations
Slaves are allocated as follows. Before a user program can access the following areas, a user-
defined variable that specifies the AT specification of that allocation area must to be defined.
OUT area 1
IN area 1
Changing the Master User-set Allocations Switch to TRUE
Change *_Sw1MstrAlocCmd (Master User-set Allocations Switch) to TRUE. The Master User-set
Allocations Switch will read the allocation results data for the above slaves and create a scan list
based on data for slaves that are actually online prior to starting remote I/O communications with the
scan list enabled.
4-30
OUT block 1 area
First word in OUT block 1
IN block 1 area
First word in IN block 1
Allocation size setup table area
First word in Allocation Size Setup Table 1
User-defined vari-
able name (USINT
type)
Slave0_InSizeTab
Slave0_OutSizeTab
Slave1_InSizeTab
Slave1_OutSizeTab
Slave2_InSizeTab
Slave2_OutSizeTab
Slave3_InSizeTab
Slave3_OutSizeTab
Slave4_InSizeTab
Slave4_OutSizeTab
Slave5_InSizeTab
Slave5_OutSizeTab
Address 0
Address 0 allocated two bytes (1 word).
Not used
Address 1
Address 1 allocated 1 byte, leftmost byte is not used.
Address 2
Address 2 allocated two bytes (1 word).
Address 5
Address 5 allocated 20 bytes (10 words).
Not used
Address 1
Address 1 allocated 1 byte, leftmost byte is not used.
Address 2
Address 2 allocated two bytes (1 word).
Not used
Address 3
Address 3 allocated 1 byte, leftmost byte is not used.
Address 5
Address 5 allocated 20 bytes (10 words).
CJ-series DeviceNet Units Operation Manual for NJ-series CPU Unit(W497)
Name
4 (WR)
50 (50 words)
4 (WR)
100 (100 words)
3 (DM)
100 (100 words)
Number of slave
Setting
bytes
0
0
2
2
1
1
1
1
2
2
2
2
1
1
0
0
0
0
0
0
20
20
20
20
Setting (function)