Cisco catalyst 3750 Command Reference Manual page 746

Hide thumbs Also See for catalyst 3750:
Table of Contents

Advertisement

show switch
A typical state transition for a member (including a master) booting up is Waiting -> Initializing ->
Ready.
A typical state transition for a member becoming a master after a master election is Ready -> Master
Re-Init -> Ready.
A typical state transition for a member in version mismatch mode is Waiting -> Ver Mismatch.
You can use the show switch command to identify whether the provisioned switch exists in the stack.
The show running-config and the show startup-config privileged EXEC commands do not provide this
information.
The display also includes stack MAC-persistency wait-time if persistent MAC address is enabled.
Examples
This example shows summary stack information:
Switch> show switch
Switch#
--------------------------------------------------------
6
*8
2
This example shows detailed stack information:
Switch> show switch detail
Switch/Stack Mac Address : 0013.c4db.7e00
Mac persistency wait time: 4 mins
Switch#
----------------------------------------------------------
*1
2
6
Switch#
--------------------------------------------------------
1
6
Catalyst 3750 Switch Command Reference
2-716
Initializing—A switch has determined whether its stack master status. If it is not the stack master,
it is receiving its system- and interface-level configuration from the stack master and loading it.
Ready—The member has completed loading the system- and interface-level configurations and can
forward traffic.
Master Re-Init—The state immediately after a master re-election and a different member is elected
master. The new master is re-initializing its configuration. This state applies only to the new master.
Ver Mismatch—A switch in version mismatch mode. Version-mismatch mode is when a switch
joining the stack has a different stack protocol minor version number than the master.
SDM Mismatch—A switch in Switch Database Management (SDM) mismatch mode. SDM
mismatch is when a member does not support the SDM template running on the master.
Provisioned—The state of a preconfigured switch before it becomes an active member of a stack, or
the state of a member after it has left the stack. The MAC address and the priority number in the
display are always 0 for the provisioned switch.
Role
Mac Address
Member
0003.e31a.1e00
Master
0003.e31a.1200
Member
0000.000.0000
Role
Mac Address
Master 0013.c4db.7e00
Member 0000.000.0000
Member 0003.e31a.1e00
Stack Port Status
Port 1
Port 2
Ok
Down
Down
Ok
Chapter 2 Catalyst 3750 Switch Cisco IOS Commands
Current
Priority
State
1
Ready
1
Ready
0
Provisioned
H/W
Current
Priority Version
State
1
0
Ready
0
0
Provisioned
1
0
Ready
Neighbors
Port 1
Port 2
6
None
None
1
OL-8552-07

Advertisement

Table of Contents
loading

Table of Contents