NOTE
The chassis features multiple mounting holes, allowing the rack mount adapters to be installed up
to 25 mm (1 in) from the face of the device.
Figure 2: Rack Mount Adapters
1. Rear
2. Front
2.
If required, install adapters on the opposite side of the device to protect from vibrations.
3.
Insert the device into the rack.
4.
Secure the adapters to the rack using the supplied hardware.
Section 2.1.2

Mounting the Device on a DIN Rail

For DIN rail installations, the RX1501 can be equipped with panel/DIN rail adapters pre-installed on each side of
the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
To mount the device to a DIN rail, do the following:
1.
Align the adapters with the DIN rails and slide the device into place.
Figure 3: DIN Rail Mounting