Valve Replacement - Regency CC40LE-NG Owners & Installation Manual

City series zero clearance direct vent gas fireplace
Table of Contents

Advertisement

maintenance

Valve Replacement

Important: Always shut off gas supply/120 volt power prior to servicing the
gas valve.
1. T urn off unit and allow to cool to room temperature.
2. R emove outer enamel or steel panels—see instructions in the panel removal
section in this manual
3. R emove outer safety glass panels and inner panels (firebox glass)–see
instructions in this manual.
4. Remove all media and logs (if installed) — set aside.
5. L oosen 4 screws in locations shown below (2 at front and 2 at rear)—slide burner
to the left away from the orifice and lift out.
front
screw locations
back screw locations
6. Remove 16 screws in locations shown below.
Remove 16 screws securing valve tray
| City Series
66
7. L ift valve tray by out partially and disconnect flexible gas connection on the
valve inlet side, remove valve tray- replace with new valve tray.
tooltip
8. Reverse steps 6-1 to complete.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cc40le-lpCc40re-ngCc40re-lp

Table of Contents