installation

Inner glass panel (firebox glass) Installation / removal

Note: glass panels must be installed to operate fireplace
WARNING: GLASS HANDLING
We recommend using the glass vacuum holders supplied by the manufac-
turer. Lower the glass to rest in a safe place, this is to prevent damage to the
glass edges. Extra care must be taken when removing/installing the glass.
Breakage or damage to the edge of the glass which occurs as a result of
careless handling will not be covered under warranty.
• W e recommend handling the glass with supplied vacuum
clamps
• When removing glass–prepare a soft, scratch resistant
surface to place the glass
• Never clean or remove hot glass
Note: The suction cups may leave a round film on the glass
when used. Ensure that the glass is cleaned using a fireplace
glass cleaner prior to operating the appliance.
Important:
Prior to installing the inner glass, ensure that there is no media present in
the bottom channel as this can cause damage to the glass. Remove any
media from bottom channel prior to installing the glass.
1. R emove outer safety glass panels if previously installed–see instructions
in this manual.
2. C C40LE/CC40RE Single sided & CC40LE/CC40RE 3 Sided Units—Re-
move outer panels installed in units - see panel removal section in this manual.
Single sided units–proceed to Step 5.
3. E nsure all 4 clamps on each side are open to allow clearance for the glass.
Lift up side panel using supplied vacuum clamp and tilt inward and upward
positioning into a top channel and lowering gently into the lower glass chan-
nel–slide the side glass panel firmly towards the back wall until the springs
at the back wall are compressed.
Bottom
Top clamps in
channel
open position
Bottom side clamps in
open position
CC40LE/CC40RE shown
| City Series
46
Push side glass
panel firmly
to back wall
until springs are
compressed—
then close
clamps.
4. W ith the springs compressed, close the 2 clamps at the bottom and 2 clamps
at the top, by turning inward, to secure the glass in position. For the 3 sided
unit, repeat on the opposite side.