CC40LE/CC40RE glass panel installation

CC40LE/CC40RE GLASS PANEL INSTALLATION
1. Turn off unit and allow to cool to room temperature. Remove the outer safety
glass and inner ceramic fi rebox glass panels and any media installed — see
manual for instructions. CC40RE shown in diagrams.
NOTE: CC40RE shown in diagrams—CC40LE panels install in the same or-
der. Installed panels for the CC40LE will appear as mirror images of diagrams
shown below.
2. Identify panels and order of installation.
3. Install the inner base panel (1) around burner as shown below.
919-744a
4. Slide the supplied bottom corner bracket behind the small panel (1) and the
corner bracket
5. Carefully manoeuvre the back glass panel (2) to the back wall of the fi rebox.
Glass Panel Parts Layout
1
back and side walls, in the orientation shown below.
back wall of unit
bottom
656-206
base panel
back wall of unit
bottom
back bracket
656-218
base panel
Center the glass panel and position bottom of panel into brackets installed in
step 4. Place the 2 top back brackets on the top edge of the glass and secure
to the unit with one screw on each side once back glass panel is in position.
bottom corner
brackets
Top back
bracket location
656-202
CITY SERIES
installation
Top back
bracket
orientation
656-202