Framing and Finishing Inset Installations CC40LE/CC40RE

1. Frame in the enclosure for the unit with framing material
Note: When constructing the framed opening ensure there is sufficient
access to install the gas lines,electrical. Also the wiring harness must be
wall mounted using the receptacle provided with the appliance. The wiring
harness will be located on the right hand side of the appliance if facing the
unit from the front. This must be done prior to any finishing.
2. F or exterior walls, insulate the enclosure to the same degree as the rest
of the house, apply vapour barrier and drywall, as per local installation
codes. (Do not insulate the fireplace itself.)
WARNING: Failure to insulate and add vapor barriers to the inside of the
exterior wall will result in operational and performance problems including, but
not limited to: excessive condensation on glass doors, poor flame package,
carbon, blue flames etc. These are not product related issues.
3. T he unit does not have to be completely enclosed in a chase. You must
maintain clearances from the vent to combustible materials: See "Clear-
ances" section. Combustible materials can be laid against the side and
back standoffs and the stove base.
4. C ombustible material (drywall,wood,wood panels, etc.) may be brought
up to this appliance (top,bottom and sides)
5. E nsure that the material being used does not encroach anywhere in the
area of the glass. This would cause dangerous operating conditions.
6. T his appliance comes with a 1/2" lip at top, sides and bottom to hide the
ends of the drywall. The 1/2" side and bottom, front and bottom side lips
supplied with the appliance can alternatively be removed and replaced
with J Style Trim or Metal Corner Bead purchased at your local hardware
store to cover cut/exposed edges of the combustible facing material or
any other finishing materials being used. Six (6) screws secure the bot-
tom front lip. Two (2) secure the bottom side lips and 2 secure the side
if deciding to remove these. These will be hidden so the outer panels (if
installed) will need to be removed to access the screws. See outer panel
removal in this manual.
7. T his appliance can also be recessed (using combustible materials) with
a hearth in front of the appliance. This can also extend to the top. See
below for details.
8. T he wall behind the unit must be closed off.
**Combustible material may extend a minimum of 1/2" and to a maximum
of 2-1/2" from the Front top and open side faces of the appliance. If 2-1/2" is
insufficient non combustible material may be used instead of combustible to
extend the finished material further out or alternatively be staggered if using
combustible materials. See mantle clearance chart for details. The base and
closed side have no limit when it comes to how far the combustible material
may extend out from the appliance.