3.
Mount One-touch M6 Brackets (or M8 Brackets) to the aluminum profile according to the position
where the sensor is mounted. The positions of One-touch M6 Brackets (or M8 Brackets) mounted to
the emitter and receiver must be aligned with each other. To mount Brackets to the aluminum profile,
insert a T-slide nut into the profile in advance with the recommended tightening torque of 11.0 N•m.
The T-slide nut is user provided. Using the T-slide nut makes the mounting work easier.
T-slide nut (Optional)
4.
The positions of Intermediate Brackets mounted to the emitter and receiver must be aligned with each
other.
Tighten the hexagon socket head cap screws (M3 x 12) of Intermediate Bracket (1) to secure the
sensor. (Figure 28)
Insert the Intermediate Bracket, which has been mounted at the bottom of the sensor, into the One-
touch M6 Bracket (or One-touch M8 Bracket) mounted to the aluminum profile. (Figure 28)
Tighten the hexagon socket head cap screws(M3 x 12) with the tightening torque at 0.54 N•m
(recommended).
Hexagon socket
head cap screw
(M3 x 12)
One-touch M6 (M8) Bracket
Figure 27
Tighten
securely
Figure 28
Wiring/Installation
Insert Intermediate
Bracket into
One-touch M6 Bracket
(One-touch M8 Bracket).
E