 Connecting a F3SJ-E to a G9SB-301-D
•Thin (22.5 mm thick)
+24 VDC
Power
supply
0 V
A1
A2
T21
TH
SA
G9SB-301-D
Unblocked
Blocked
External test/lockout reset switch
(S1)
Interlock reset switch
(S2)
Emergency stop switch
(S3)
Safety output
K1,K2 N.O. contact
KM1,KM2 N.O. contact
K1,K2 N.C. contact
KM1,KM2 N.C. contact
Use G9SB-301-B for auto reset with three N.O. and one N.C. contacts.
Use G9SB-200-D for manual reset with two N.O. contacts, or use G9SB-200-B for auto reset with two N.O. contacts.
For more information, visit OMRON's website at http://www.omron.com/
Communication
line (+) (Gray)
Communication
line (-) (Pink)
12
Feedback loop
11
KM1
KM2
23
T11
T12
T32
13
T22
T31
K1
K2
K1
K1
K2
Control
a
K2
Circuit
K1
a K2
14 24 34 42
KM1
*1 The G9SB-200-D (17.5 mm thick), with no 33-34 and 41-42, is also available.
*2 If an emergency stop switch is not used, connect safety output 1 to T12
terminal and safety output 2 to T22 directly.
S1
S2
S3
KM1,KM2: Safety relay with force-guided contact (G7SA) or magnetic contactor
M
Input/Output Circuit and Applications
- G9SB-301-D settings
- Manual reset mode
- Using feedback loop
- Using emergency stop switch
KM1
KM2
*2
22
21
S3
M
*1
*1
33
41
*1
*1
KM2
: External test/lockout reset switch
(connect to 0V if a switch is not required)
: Interlock reset switch
: Emergency stop switch (force-opening contact)
(A165E, A22E)
: 3-phase motor
E
F3SJ-E/B