Omron F3SJ-E0185P25 User Manual page 111

F3sj-e series safety light curtain
Table of Contents

Advertisement

 Muting system
F39-JD A-L
B1
A1
S1
S1
: External test switch (connect to 0 V if a switch is not required)
S2
: Lockout reset switch (connect to 24 V if a switch is not required)
A1
: Contact by muting sensor A1
B1
: Contact by muting sensor B1
KM1,KM2: Safety relay with force-guided contact (G7SA) or magnetic contactor
ML
: External indicator
M
: 3-phase motor
*1. Also used for override input.
*2. Under muting system, connect to 0 V as the external device monitoring cannot be used.
Unblocked
Blocked
External test switch (S1)
Muting input 1
Muting input 2
Safety output
KM1, KM2 N.O. contact
KM1, KM2 N.C. contact
External indicator
Communication line (+) (Gray)
Communication line (-) (Pink)
KM1
KM2
S2
Input/Output Circuit and Applications
- Does not use external device monitoring function
F39-JD A-D
ML
KM1
KM2
KM1
KM2
M
+24 VDC
Power
supply
0 V
E
F3SJ-E/B
95
User's Manual