Omron F3SJ-E0185P25 User Manual page 115

F3sj-e series safety light curtain
Table of Contents

Advertisement

 Connecting a F3SJ-E to a G9SP
•Emergency stop switch can be connected
•Door switch, two hand control, single beam sensor, or relay unit can be used in combination with
G9SP.
Communication line (+) (Gray)
Communication line (-) (Pink)
S3
V1
Si0
Si1
G1
T0
T1
+24 VDC
Power
0 V
supply
11
21
GND
12
22
S1
Unblocked
Blocked
External test/lockout reset switch
(S3)
Reset switch
(S2)
Emergency stop switch
(S1)
Safety output
KM1,KM2 N.O. contact
KM1,KM2 N.C. contact
Si2
Si3
Si4
Si5
Input/Output Circuit and Applications
Si6
Si7
V2
T2
T3
G2
+24 VDC
0 V
KM1
GND
KM2
S2
Feedback loop
S1
: Emergency stop switch (force-opening contact) (A165E, A22E)
S2
: Reset switch
S3
: External test/lockout reset switch
(connect to 0 V if a switch is not required)
KM1, KM2
: Safety relay with force-guided contact (G7SA)
or magnetic contactor
M
: 3-phase motor
- G9SP settings
- Manual reset mode
- Using feedback loop
+24 VDC
Power
supply
0 V
So0
So1
KM1
G2
G2
KM2
Power
supply
KM1
KM2
M
F3SJ-E/B
User's Manual