Omron F3SJ-E0185P25 User Manual page 110

F3sj-e series safety light curtain
Table of Contents

Advertisement

Input/Output Circuit and Applications
 Muting system
F39-JD A-L
B1
A1
S1
: External test switch (connect to 0 V if a switch is not required)
S2
: Reset switch
S3
: Lockout reset switch (connect to 24 V if a switch is not required)
A1
: Contact by muting sensor A1
B1
: Contact by muting sensor B1
K1,K2,K3 : Safety relay with force-guided contact (G7SA)
KM1,KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor
ML
: External indicator
M
: 3-phase motor
*1. Also used for override input.
*2. Under muting system, connect to 0 V as the external device monitoring cannot be used.
External test switch
K1,K2 N.C. contact
K1,K2 N.O. contact
KM1,KM2 N.C. contact
KM1,KM2 N.O. contact
Enable reset switch S2 for long enough with the consideration of the operating time or recovery time of each relay that
you use.
F3SJ-E/B
94
User's Manual
Communication line (+) (Gray)
Communication line (-) (Pink)
S1
S3
Unblocked
Blocked
Reset switch
(S2)
(S1)
Safety output
K3 N.C. contact
K3 N.O. contact
Muting input 1
Muting input 2
External indicator
- Does not use external device
monitoring function
F39-JD A-D
KM1
Feedback loop
KM2
S2
K3
K1
K3
K2
K3
ML
K1
K2
+24 V
+24 V
K1
K2
K3
KM1
KM2
+24 V
K1
K2
K3
+24 VDC
Power
supply
0 V
KM1
K1
KM2
K2
K3
M

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents