To enable the muting function, D3 and d2 must satisfy formulas (3) and (4), respectively.
This distance must prevent the muting function from being enabled by a person passing through the
muting sensors. Also, install the F3SJ-B and muting sensors so that each workpiece passes through
all muting sensors before the next workpiece arrives at the first muting sensor.
Workpiece
Moving direction
<Wiring diagram>
Using a photoelectric switch as a muting sensor
B1
A1
F3SJ-B
* Two-wire type muting sensor cannot be used.
Workpiece
B2
A1, B1, A2, B2 :
Retro-reflective
photoelectric switch
- PNP Output
- ON when Interrupted
A2
System Configuration and Functions
Workpiece
Workpiece
Moving direction
Using an N.O. contact type switch as a muting sensor
A1
A2
B1
B2
A1, A2, B1, B2:
N.O. contact type switch
+24 VDC