Configure Line-timing as the Timing Source
Configure Line-timing as the Timing Source
Use the following example to configure line-timing as the timing source:
configure
port atm slot#/port#
port bits slot#/port#
For additional information, refer to the ATM Port Configuration Mode Commands (OLC) and Channelized
Port Configuration Mode Commands (CLC) chapters of the Command Line Interface Reference.
Save the configuration as described in the Verifying and Saving Your Configuration chapter.
Configure Both BITS and Line as Timing Sources
Use the following example to configure both BITS and line-timing as the timing sources:
configure
card CLC_slot#
port atm OLC_slot#/port#
port channelized CLC_slot#/port#
port bits slot#/port#
Save the configuration as described in the Verifying and Saving Your Configuration chapter.
Confirming the Timing Source
Use the show timing command, documented in the Exec Mode Commands chapter of the Command Line
Interface Reference, to confirm that the timing source has been configured correctly.
ASR 5000 System Administration Guide, StarOS Release 21.1
44
line-timing
no shutdown
exit
recover line1 linecard_slot #
shutdown
end
framing mode
exit
line-timing
no shutdown
exit
line-timing
no shutdown
exit
recover line1 LC_slot#/port#
recover line2 LC_slot#/port#
no shutdown
end
System Settings