Siemens SIMATIC S7-400 Reference Manual page 64

Automation system module data
Hide thumbs Also See for SIMATIC S7-400:
Table of Contents

Advertisement

Power supply modules
3.9 Power supply modules PS 407 10A (6ES7407-0KA02-0AA0) and PS 10A R (6ES7407-0KR02-0AA0)
PS 407 10A and PS 407 10A R technical specifications
Dimensions W x H x D (mm)
Weight
Cable cross-section
Input voltage
● Rated value
● Permitted range
Line frequency
● Rated value
● Permitted range
Rated input current
● With 120 V AC
● With 120 V DC
● At 230 V AC
● At 230 V DC
Inrush current
● At 230 V AC
● At 300 V DC
Leakage current
Output voltage
● Rated values
Output current
● Rated values
Protection class pursuant to IEC 60536
Overvoltage category
Pollution degree
Rated voltage U
0 < U
150 V < U
Backup for power failures
Power consumption
Power loss
Backup current
64
Dimensions, weight and cable cross-sections
e
≤ 50 V
e
≤ 300 V
e
50x290x217
1.2 kg
3x1.5 mm
(stranded wire with wire end ferrule with
2
insulating sleeve; use hose line only)
Input variables
120/230 V DC
120/230 V AC
88 to 300 V DC
85 to 264 V AC
(wide range input)
50/60 Hz
47 to 63 Hz
0.9 A
1.0 A
0.5 A
0.5 A
Peak value 63 A, full width at half maximum 1 ms*
Peak value 58 A, full width at half maximum 1 ms*
< 3.5 mA
Output variables
5.1 V DC/24 V DC
5 V DC: 10 A
24 V DC: 1.0 A
Parameters
I, with protective conductor
II
2
Test voltage
700 V DC (secondary <-> PE)
2200 V DC (primary <-> secondary/PE)
> 20 ms
at a repeat rate of 1 s, meets NAMUR recommen‐
dation NE 21
95 W
20 W
maximum of 100 µA when power off
S7-400 Automation System Module Data
Reference Manual, Ausgabe 11/2016, A5E00850736-08

Hide quick links:

Advertisement

Table of Contents
loading