Siemens SIMATIC S7-400 Reference Manual page 165

Automation system module data
Hide thumbs Also See for SIMATIC S7-400:
Table of Contents

Advertisement

Properties
AI 8 x 13 bit
Maximum permitted
between
common mode volt‐
channels or
age
between ref‐
erence po‐
tential of
connected
sensors and
M
30 V AC
External power sup‐
No
ply required
Special features
-
2-DMU 2-wire transducer
1
Table 5-2
Number of outputs
Resolution
Type of output
Configurable diagnostics
Diagnostic interrupt
S7-400 Automation System Module Data
Reference Manual, Ausgabe 11/2016, A5E00850736-08
SM 431;
SM 431;
AI 8 x 14 bit
(-1KF00-)
(-1KF10-)
between
channels or
between
channel and
central
grounding
point:
60 V DC /
ANA:
30 V AC
(SELV)
24 V DC (on‐
ly with cur‐
rent, 2
DMU)
1
Suitable for
temp. meas‐
urement
Tempera‐
ture sensor
types config‐
urable
Lineariza‐
tion of sen‐
sor charac‐
teristic
curves
Measured
value
smoothing
can be set
Analog output modules: Summary of features
Properties
SM 431;
SM 431;
AI 8 x 14 bit
AI 16 x 13 bit
(-1KF20-)
(-0HH0-)
between
between
channels or
channels or
between ref‐
between ref‐
erence po‐
erence po‐
tential of
tential of
connected
connected
sensors and
sensors and
M
central
ANA:
grounding
8 V AC
point:
2 V DC/AC
24 V DC (on‐
24 V DC (on‐
ly with cur‐
ly with cur‐
rent, 2
rent, 2
DMU)
DMU)
1
1
Rapid A/D
-
change,
suitable for
highly dy‐
namic pro‐
cesses
Measured
value
smoothing
can be set
8 outputs
13 bits
Channel by channel:
● Voltage
● Current
No
No
Analog modules
5.2 Module overview
SM 431;
SM 431;
AI 16 x 16 bit
AI 8 x RTD
16 bit
(-7QH00-)
(-7KF10-)
between
between
channels or
channel and
between
central
channel and
grounding
central
point:
grounding
60 V DC /
point:
30 V AC
60 V DC /
(SELV)
30 V AC
(SELV)
24 V DC (on‐
No
ly with cur‐
rent, 2
DMU)
1
Suitable for
Resistance
temp. meas‐
thermome‐
urement
ter configu‐
rable
Tempera‐
ture sensor
Lineariza‐
types config‐
tion of sen‐
urable
sor charac‐
teristic
Lineariza‐
curves
tion of sen‐
sor charac‐
Measured
teristic
value
curves
smoothing
can be set
Measured
value
smoothing
can be set
Module
SM 432; AO 8 x 13 bit
(-1HF00-)
SM 431;
AI 8 x 16 bit
(-7KF00-)
between
channels or
between
channel and
central
grounding
point:
60 V DC /
30 V AC
(SELV)
No
Internal
measure‐
ment resist‐
ance
Field con‐
nection with
internal ref‐
erence tem‐
perature (in‐
cluded in
module
scope of de‐
livery)
Measured
value
smoothing
can be set
165

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents