Configuring Ethernet OAM and CFM
Link fault action:
Dying gasp action:
Critical event action: no action
Link Monitoring
---------------
Status: supported (on)
Symbol Period Error
Frame Error
Frame Period Error
Frame Seconds Error
Receive-Frame CRC Error
Transmit-Frame CRC Error: Not Supported

Enabling Ethernet OAM Remote Loopback

You must enable Ethernet OAM remote loopback on an interface for the local OAM client to initiate
OAM remote loopback operations. Changing this setting causes the local OAM client to exchange
configuration information with its remote peer. Remote loopback is disabled by default.
Remote loopback has these limitations:
To enable Ethernet OAM remote loopback on an interface, follow these steps:
Command
Step 1
Switch# configure terminal
Step 2
Switch(config)# interface interface-id
OL-28731-01
no action
no action
Window:
100 x 1048576 symbols
Low threshold:
1 error symbol(s)
High threshold:
none
Window:
10 x 100 milliseconds
Low threshold:
1 error frame(s)
High threshold:
none
Window:
1000 x 10000 frames
Low threshold:
1 error frame(s)
High threshold:
none
Window:
100 x 100 milliseconds
Low threshold:
1 error second(s)
High threshold:
none
Window:
10 x 100 milliseconds
Low threshold:
10 error frame(s)
High threshold:
none
Only data packets are looped back.
You cannot configure Ethernet OAM remote loopback on ISL ports or ports that belong to an
EtherChannel.
Remote loopback can be supported on a max of 16 ports.
Purpose
Enters global configuration mode.
Defines an interface to configure as an EOM interface, and
enters interface configuration mode.