Cisco Catalyst 4500 series Administration Manual page 1643

Hide thumbs Also See for Catalyst 4500 series:
Table of Contents

Advertisement

Chapter 66
Configuring Ethernet OAM and CFM
To configure Ethernet OAM link monitoring on an interface, perform this task:
Command
Step 1
Switch# configure terminal
Step 2
Switch(config)# interface interface-id
Step 3
Switch(config-if)# ethernet oam link-monitor
supported
Step 4
Switch(config-if)# ethernet oam link-monitor
symbol-period
} |
{
none
low
low-symbols
Repeat this step to configure both high and low
thresholds.
Step 5
Switch(config-if)# ethernet oam link-monitor
{
frame
threshold
{
low
low-frames
Repeat this step to configure both high and low
thresholds.
OL-28731-01
{
{
{
threshold
high
high symbols
}} |
window symbols
{
{
|
high
high-frames
}} |
window milliseconds
Purpose
Enters global configuration mode.
Defines an interface, and enters interface configuration
mode.
Enables the interface to support link monitoring. it is the
default.
You need to enter this command only if it has been disabled
by previously entering the no ethernet oam link-monitor
supported command.
(Optional) Configures high and low thresholds for an
|
error-symbol period that trigger an error-symbol period
}
link event.
Enter threshold high high-symbols to set a high
threshold in number of symbols. The range is 1 to
65535. The default is none.
Enter threshold high none to disable the high
threshold if it was set. it is the default.
Enter threshold low low-symbols to set a low
threshold in number of symbols. The range is 0 to
65535. It must be lower than the high threshold.
Enter window symbols to set the window size (in
number of symbols) of the polling period. The range is
1 to 65535 symbols.
(Optional) Configures high and low thresholds for error
} |
none
frames that trigger an error-frame link event.
}
Enter threshold high high-frames to set a high
threshold in number of frames. The range is 1 to
65535. The default is none.
Enter threshold high none to disable the high
threshold if it was set. it is the default.
Enter threshold low low-frames to set a low threshold
in number of frames. The range is 0 to 65535. The
default is 1.
Enter window milliseconds to set the a window and
period of time during which error frames are counted.
The range is 10 to 600 and represents the number of
milliseconds in multiples of 100. The default is 100.
Software Configuration Guide—Release IOS XE 3.6.0E and IOS 15.2(2)E
Enabling and Configuring Ethernet OAM
66-39

Advertisement

Table of Contents
loading

Table of Contents