Configuring Ethernet CFM
Command
Step 11
Switch(config-ip-sla-ethernet-monitor)#
timeout milliseconds
Step 12
Switch(config-ip-sla-ethernet-monitor)# exit
Step 13
Switch(config)# ip sla schedule
operation-number [ageout seconds] [life
{forever | seconds}] [recurring] [start-time
{hh:mm {:ss} [month day | day month] | pending
| now | after hh:mm:ss}]
Step 14
Switch(config)# end
Step 15
Switch# show ip sla configuration
[operation-number]
Step 16
Switch# copy running-config startup-config
To remove an IP SLAs operation, enter the no ip sla operation-number global configuration command.
The following example shows how to configure an IP SLA CFM Probe or Jitter Operation:
Switch(config)# ip sla 1
Switch(config-ip-sla)# ethernet echo mpid 23 domain abc vlan 5
Switch(config-ip-sla-ethernet-echo)# exit
Switch(config)# ip sla schedule 1 start-time now
Switch# show ip sla configuration 1
IP SLAs, Infrastructure Engine-II.
Entry number: 1
Owner:
Tag:
Type of operation to perform: 802.1ag Echo
Software Configuration Guide—Release IOS XE 3.6.0E and IOS 15.2(2)E
66-20
Chapter 66
Purpose
(Optional) Specifies the amount of time in ms that the IP
SLAs operation waits for a response from its request
packet. The range is 0 to 604800000; the default value is
5000.
Returns to global configuration mode.
Schedules the time parameters for the IP SLAs operation.
operation-number—Enter the IP SLAs operation
number.
(Optional) ageout seconds—Enter the number of
seconds to keep the operation in memory when it is not
actively collecting information. The range is 0 to
2073600 seconds. The default is 0 seconds.
(Optional) life—Set the operation to run indefinitely
(forever) or for a specific number of seconds. The
range is from 0 to 2147483647. The default is 3600
seconds (1 hour)
(Optional) recurring—Set the probe to be
automatically scheduled every day.
(Optional) start-time—Enter the time for the
operation to begin collecting information:
To start at a specific time, enter the hour, minute,
second (in 24-hour notation), and day of the
month.
Enter pending to select no information collection
until a start time is selected.
Enter now to start the operation immediately.
Enter after hh:mm:ss to show that the operation
should start after the entered time has elapsed.
Returns to privileged EXEC mode.
Shows the configured IP SLAs operation.
(Optional) Saves your entries in the configuration file.