Fourth Edition · First Printing
Observe and Obey:
Only routine maintenance items specified in this
manual shall be performed by the operator.
Scheduled maintenance inspections shall be
completed by qualified service technicians,
according to the manufacturer's specifications
and the requirements specified in the
responsibilities manual.
Maintenance Symbols Legend
The following symbols have been
used in this manual to help
communicate the intent of the
instructions. When one or more of
the symbols appear at the
beginning of a maintenance
procedure, it conveys the meaning
below.
Indicates that tools will be required to
perform this procedure.
Indicates that new parts will be required to
perform this procedure.
Indicates that a cold engine is required
before performing this procedure.
Part No. 82315
Check the Engine Oil Level
Maintaining the proper engine oil level is essential
to good engine performance and service life.
Operating the machine with an improper oil level
can damage engine components.
1 Check the oil dipstick.
Ford models:
Result: The oil level should be between the
and
marks. Add oil as needed.
SAFE
Deutz models:
Result: The oil level should be within the two
marks on the dipstick. Add oil as needed.
Ford LRG-425 EFI Engine
Oil viscosity requirements
below 60°F / 15.5°C
-10° to 90°F / -23° to 32°C
above -10°F / -23°C
above 25°F / -4°C
Use oils meeting API classification SH or SG grade.
Units ship with 10-40 CC/SG.
Genie Z-60/34
Operator's Manual

Maintenance

Check the oil level with the
engine off.
ADD
5W-30
5W-30
5W-30
10W-30
13