Navigating IntelliChem
The following examples show how to navigate the main menus and sub-menus. Press
the MENU button to access the main menu. Press the  Right arrow button to select
a menu item and select items in a sub-menu. Press / to select previous/next item
on a page. To change a menu setting or value press the / Up/Down arrow button.
Press the MENU button to exit and return to the previous menu items. Note: Settings are
automatically save when changed.
Example: To change the pH dosage settings (pH Dosage screens 1/2 and 2/2):
Press MENU / pH Menu  pH Dosage 
pH Menu
ORP Menu
Saturatn Index
Auto Setup
ORP Menu
Saturatn Index
Auto Setup
Configuration
pH Dosage
pH Setpt: 7.5
pH Tweak
pH Supplies
pH Dosage
Dose: by Volume
Mixing Time:
H:00 M:59
pH Dosage
Dose Limit Units
3
21
[oz]
Clear [Power-On]
pH Dosage
Dose: by Volume
Mixing Time:
H:09 M:59
pH Menu
ORP Menu
Auto Setup
Configuration
pH
OK
7.46
Mixing 00:07:03
ORP OK
450
Mixing 00:07:54
Controller Menus
®
Press the / Up/Down arrow button to scroll
1.
through the main menu items. For this example
choose pH menu.
2.
Press the  Right arrow button to select the
pH menu.
Press  arrow button to select pH Dosage (page
3.
1 of 2). Press / to toggle between pH Dosage
page 1/2 and page 2/2.
4.
From pH Dosage page 1/2, press the  to select
Dose (feed method). To change the feed method
press / to change the selection: "by Volume" or
"by Time".
5.
Press the  to select the next item. The cursor
1/2
moves down to the "Mixing Time" hours setting
(H:00).
6.
Press the / to adjust the Mixing Time hours
between feeding acid. Press  to select the
minutes. Press
2/2
/ to adjust the minutes. After adjustment, the
display shows the new setting. Note: Press either
/ button to scroll forward or backwards within
this sub-menu.
Select 1/2 page indicator. Press the / buttons to
7.
select the next pH Dosage screen (2/2).
1/2
8.
Use / buttons and / buttons to select and
change the "Dose" (amount of liquid dispensed
before waiting for a mix time), Limit (amount of
liquid dispensed in one day, Units (apply to dose
and limit) and clear dose limits setting.
Press the MENU to return to the previous pH
9.
Dosage page 1/2 menu items.
10. Press the MENU again to exit pH Dosage menu.
Note: All settings are immediately save when
changed.
INTELLICHEM
Controller Installation and User's Guide
®
11