30
Mounting IntelliChem
Mount the IntelliChem controller enclosure as follows:
1.
Select a location for mounting the IntelliChem® Controller enclosure with
the following required recommendations:
2.
Install the IntelliChem controller enclosure at least 10 feet from the pool
or spa wall.
3.
Supply power must be routed to the IntelliChem controller in accordance
with the applicable national and current local (NEC) codes (see page i).
4.
The installation surface must be solid and vertical. Do not mount the
IntelliChem controller enclosure in a horizontal position.
5.
Maintain adequate clearance for opening the enclosure.
6.
The environment should be free of chemical fumes and excessive heat.
The maximum temperature it should not exceed is 110 ºF (50 C).
7.
Mount as far as possible from sources of electrical interference.
8.
Mount the enclosure on a flat surface.
9.
Hold the enclosure against the mounting surface with a closed lid and
mark the location of the mounting brackets located on the sides of the
enclosure next to the wall. Prepare holes as necessary and secure
enclosure using the provided mounting screws.
10. Install a conduit into the controller enclosure.
pumps on when both flow cell valves are closed. Increased pressure may cause
the feed lines to blow off and spray full strength chemicals on anyone or anything
near the equipment. Securely fasten all electrical, water, and chemical lines.
MOUNTING
HOLES
INTELLICHEM
Controller Installation and User's Guide
®
Controller Enclosure
®
Locate the chemical feed pumps and the chemical storage
tanks in a safe and secure area. Never turn the chemical feed