Maintenance Plan - High Pressure Pump; Every 40 Hours Of Operation - At Least Once A Week; Every 200 Hours Of Operation - At Least Once Every 3 Months - Alto CS 1020 PE Operating Instructions Manual

Table of Contents

Advertisement

Earth continuity checks should be carried out on the machine, and on its fixed wiring installation, when the
equipment is installed, and at regular intervals afterwards.
4.6
Guarantee
Our General Terms of Sale and Delivery do prevail.
This Guarantee only covers proved defects of material and of workmanship.
In order to obviate non-justified claims, we are enumerating below those keypoints, which shall not be covered
by this Guarantee:
Damages caused by changing the machine´s adjustment.
Damages of transportation.
Damages due to careless handling by the orderer, or due to violence.
Damages caused by non-observance of our Decalcifying Instructions.
Damages caused by non-observance of our Operating Instructions.
Damages on products other than ours are handled according to the Guarantee of the respective manufacturer.
Damages occuring on hoses shall be only subject to guarantee if the manufacturer has recognized the damage
after examination.
Damages occuring on packings, seals, ignition electrodes, high pressure nozzles and other items, which are due
to normal wear.
5
Maintenance
5.1
Maintenance Plan - drive motor
Refer to Honda Operating Instructions
5.2

Maintenance Plan - high pressure pump

Every 40 hours of operation - at least once a week

Pump oil level control - control oil level regularly at dipstick of oil filler plug - if ncessary, refill with gear lubricant
oil. Change oil whenever it shows a greyish or white shade.
Clean filter (at water feed)
Clean filter (at pump)

Every 200 hours of operation - at least once every 3 months

Pump oil change - for inst. ARAL DEGOL BG 220, Shell Omala 220, Mobil Gear 630
V-belt tightening - if neccesary, regulate at generator
Igniter - ignition transformer, ignition cable, ignition electrodes (to e cleaned) , replace defective parts.
Oil nozzle - clean it.
Oil fiter - clean it.
Solenoid valve - clean it, clean strainer.
In case of necessity - but at least every 12 monts
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1020 de

Table of Contents