Print Mode
6.3.6

Example for Configuring the CP 523 in Print Mode

Start address 128 is set on the CP 523. Configure the CP as follows:
Parameters for the serial interface
- 2400 baud
- Even parity
- No BUSY signal
- RS-232-C (V.24) interface
- 7 data bits (11-bit frame)
- Handshake OFF
Parameters for waiting times
Not significant since XON/XOFF protocol is to be used
XON/XOFF protocol
- XON character: DC 1
- XOFF character: DC 3
Configuration data for entering message texts
No change with respect to default values
Configuration data for message text printout
- Time of day and date unchanged with respect
to default values
- Page format:
- Header:
Footer:
Entry on the PG 685 for DB 1
:
KS = 'Parameters for the serial';
:
S = 'interface';
:
KS = ':0600100';
:
S = 'XON/XOFF protocol';
:
KS = ':2';
:
KH = 1113
:
S = 'Message text printout';
:
KS = ':5';
KH = 400A
KS = 'B'
:
S = 'Headers and footers';
:
KS = ':6K1Test mode$';
:
S = 'F1Laboratory$';
:
6-14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (parameter block 0)
(6)
(0)
(0)
(1)
(0)
(0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (parameter block 1)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (parameter block 2)
(11
)
H
(13
)
H
. . . . . . . . . . . . . . . . . . . . . . . ( parameter block 3)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (parameter block 4)
64 lines/page
. . . . . . . . . . . . . . . . .(parameter block 5)
10 characters left margin
Page number at bottom
"Test mode"
. . . . . . . . . . . . . . . . . .(parameter block 6)
"Laboratory"
Parameter block 0
2400 baud (6
No BUSY signal (0
interface (1
7 data bits (0
Handshaking OFF (0
Parameter block 2
XON character: DC 1 (11
XOFF character: DC 3 (13
Parameter block 5
64 lines/page (40
margin (0A
Page number at bottom
Parameter block 6
Header 1: Test mode
Footer 1. Laboratory
Explanation
), Even parity (0
),
H
H
), RS-232-C (V.24)
H
),
H
), (11-bit frame)
H
),
H
)
H
)
H
), 10 characters left
H
)
H
EWA 4NEB 811 6044-02a