CP 523
A.2
Job Requests in Print Mode
Table A-2. Permissible Job Requests to the CP 523 in Print Mode (CPU to CP) ( 6.7)
Byte 0
7
6
5
4
3
2
1
0
0
0
0
Message text number
1
0
0
2
3
Message text number
4
Message text number
5
0
6
0
7
0
8
0
9
0
9
0
9
0
= Print requests. These are written into the message buffer if necessary.
EWA 4NEB 811 6044-02a
Byte 1
7
6
5
4
3
2
1
0
0
0
Day of the week
setting
Page number
0
0
0
0
0
0
0
0
0
0
2
0
7
0
Job Request
Read status byte, status of the printer and
current clock data
Print message text with CR/LF at end
Set clock (settings in bytes 1 to 7)
Print message text with CR/LF at end
Print message text without CR/LF at end
Print message text without CR/LF at end
Form feed
Line feed
Clear message buffer
Print all messages
Transfer parameter setting data
-
Set serial interface parameters
-
Set XON/XOFF character parameters
-
Select Print mode
Summary
A-3